Search results for "COMPASS experiment"
showing 10 items of 25 documents
Contribution of exclusive diffractive processes to the measured azimuthal asymmetries in SIDIS
2019
Hadron leptoproduction in Semi-Inclusive measurements of Deep-Inelastic Scattering (SIDIS) on unpolarised nucleons allows one to get information on the intrinsic transverse momentum of quarks in a nucleon and on the Boer-Mulders function through the measurement of azimuthal modulations in the cross section. These modulations were recently measured by the HERMES experiment at DESY on proton and deuteron targets, and by the COMPASS experiment using the CERN SPS muon beam and a $^6$LiD target. In both cases, the amplitudes of the $\cos\phi_h$ and $\cos 2\phi_h$ modulations show strong kinematic dependences for both positive and negative hadrons. It has been known since some time that the measu…
New analysis of ηπ tensor resonances measured at the COMPASS experiment
2018
We present a new amplitude analysis of the $\eta\pi$ $D$-wave in $\pi^- p\to \eta\pi^- p$ measured by COMPASS. Employing an analytical model based on the principles of the relativistic $S$-matrix, we find two resonances that can be identified with the $a_2(1320)$ and the excited $a_2^\prime(1700)$, and perform a comprehensive analysis of their pole positions. For the mass and width of the $a_2$ we find $M=(1307 \pm 1 \pm 6)$~MeV and $\Gamma=(112 \pm 1 \pm 8)$~MeV, and for the excited state $a_2^\prime$ we obtain $M=(1720 \pm 10 \pm 60)$~MeV and $\Gamma=(280\pm 10 \pm 70)$~MeV, respectively.
The experience of building and operating COMPASS RICH-1
2010
COMPASS RICH-1 is a large size gaseous Imaging Cherenkov Detector providing hadron identification in the range from 3 to 55 GeV/c, in the wide acceptance spectrometer of the COMPASS Experiment at CERN SPS. It uses a 3 m long C(4)F(10) radiator, a 21 m(2) large VUV mirror surface and two kinds of photon detectors: MAPMTs and MWPCs with CsI photocathodes, covering a total of 5.5 m(2). It is in operation since 2002 and its performance has increased in time thanks to progressive optimization and mostly to a major upgrade which was implemented in 2006. The main characteristics of COMPASS RICH-1 components are described and some specific aspects related to the radiator gas system, the mirror alig…
The Deuteron Spin-dependent Structure Function g1(d) and its First Moment
2007
We present a measurement of the deuteron spin-dependent structure function g1d based on the data collected by the COMPASS experiment at CERN during the years 2002-2004. The data provide an accurate evaluation for Gamma_1^d, the first moment of g1d(x), and for the matrix element of the singlet axial current, a0. The results of QCD fits in the next to leading order (NLO) on all g1 deep inelastic scattering data are also presented. They provide two solutions with the gluon spin distribution function Delta G positive or negative, which describe the data equally well. In both cases, at Q^2 = 3 (GeV/c)^2 the first moment of Delta G is found to be of the order of 0.2 - 0.3 in absolute value.
Measurement of the Spin Structure of the Deuteron in the DIS Region
2005
We present a new measurement of the longitudinal spin asymmetry A_1^d and the spin-dependent structure function g_1^d of the deuteron in the range 1 GeV^2 < Q^2 < 100 GeV^2 and 0.004< x <0.7. The data were obtained by the COMPASS experiment at CERN using a 160 GeV polarised muon beam and a large polarised 6-LiD target. The results are in agreement with those from previous experiments and improve considerably the statistical accuracy in the region 0.004 < x < 0.03.
Design and construction of the fast photon detection system for COMPASS RICH-1
2010
International audience; New photon detectors, based on the use of multi-anode photo-multiplier tubes coupled to individual lens telescopes and read out with a dedicated read-out electronics system, equip the central region of the Cherenkov imaging counter RICH-1 of the COMPASS experiment at CERN SPS. They are characterised by high photon yield, fast response and high rate capability and are successfully in operation since the 2006 COMPASS data taking. The photon detection system fully matches the expected performance. The design and construction of the photon detectors are described in detail.
Particle identification with COMPASS RICH-1
2011
International audience; RICH-1 is a large size RICH detector in operation at the COMPASS experiment since 2001 and recently upgraded implementing a new photon detection system with increased performance.A dedicated software package has been developed to perform RICH-1 data reduction, pattern recognition and particle identification as well as a number of accessory tasks for detector studies.The software package, the algorithms implemented and the detector characterisation and performance are reported in detail.
The COMPASS experiment at CERN
2007
The COMPASS experiment makes use of the CERN SPS high-intensitymuon and hadron beams for the investigation of the nucleon spin structure and the spectroscopy of hadrons. One or more outgoing particles are detected in coincidence with the incoming muon or hadron. A large polarized target inside a superconducting solenoid is used for the measurements with the muon beam. Outgoing particles are detected by a two-stage, large angle and large momentum range spectrometer. The setup is built using several types of tracking detectors, according to the expected incident rate, required space resolution and the solid angle to be covered. Particle identification is achieved using a RICH counter and both…
The fast photon detection system of COMPASS RICH-1
2007
Abstract A fast photon detection system has been built for the upgrade of COMPASS RICH-1, the large size gaseous RICH detector in use at the COMPASS Experiment at the CERN SPS since 2001. The photon detectors of the central region have been replaced by a new system based on multi-anode photomultipliers coupled to individual fused silica lens telescopes and a fast readout electronics system, while in the outer region the existing MWPCs with CsI photocathodes have been equipped with a new readout system, based on the APV chip. RICH-1 has been successfully operated in its upgraded version during the 2006 run. We report on the upgrade design and construction, and on the preliminary characteriza…
Triangle Singularity as the Origin of the a1(1420)
2021
The COMPASS Collaboration experiment recently discovered a new isovector resonancelike signal with axial-vector quantum numbers, the a 1 ( 1420 ) , decaying to f 0 ( 980 ) π . With a mass too close to and a width smaller than the axial-vector ground state a 1 ( 1260 ) , it was immediately interpreted as a new light exotic meson, similar to the X , Y , Z states in the hidden-charm sector. We show that a resonancelike signal fully matching the experimental data is produced by the decay of the a 1 ( 1260 ) resonance into K * ( → K π ) K ¯ and subsequent rescattering through a triangle singularity into the coupled f 0 ( 980 ) π channel. The amplitude for this process is calculated using a new a…